Limit of Application
|
|
This Specification is applied to the deducting discharger used for C.R.T
|
|
|
|
Model Name
|
|
(example)
|
S
|
2
|
3
|
|
(1)
|
(2)
|
(3)
|
|
|
|
|
(1) Type
|
|
(2) Upper limit of discharge voltage
|
|
(3) Lower limit of discharge voltage
|
|
|
|
Test Conditions
|
|
Standard test must be done at the ambient temperature of 5°C -35°C and with relative humidity of 45%-95%
|
|
|
|
Structure, size and performance
|
|
The details of structure, size and performance are prescribed in an annexed list
|
|
|
|
Packing
|
|
Packing must be done firmly not to be destroyed during transportation and custody. Model name, quantities and the date of production must be written on a pakage
|
|
|
|
|
TEST METHOD
|
|
Item
|
Specifications
|
Method of measurement
|
Rated Voltage
|
900V ~ 1500V
|
Measure, applying voltage in circuit 1
|
insulation Resistance
|
5000MΩ??
|
DC 500V is applied in circuit 1, then measure within 20 seconds
|
Discharge life test
|
Discharge Voltage
|
900V ~ 1500V
|
After repeating discharge 10 thousand times with applying DC 2KV by citcuit 2, Measure by circuit 1
|
Insulation resistance
|
5,000MΩ??
|
The same as above
|
moisture resistance test
|
Discharge Voltage
|
900V ~ 1500V
|
After removing moisture from a cabineet maintained at the temperature of 40°C±20°C with relative gumidity of 90~95°C for 250hrs, measure by circuit 1 within 2~5hrs
|
Insulation test
|
5,000MΩ??
|
The same as above
|
Strength test of termination
|
Tear test
|
Should not destyoyed
|
Lead wire should not be extracted against ourward forces of 1kg
|
Flex test
|
Should not destyoyed
|
With force of 0.5kg, Bend right and left each time at an angle of 90° °
|
|
|
|
|
|
|
STRUCTURE AND SIZE
|
|
|
|
A
|
B
|
C
|
D
|
E
|
71 m/m
|
91 m/m
|
50.5 m/m
|
0.650.1 m/m
|
4.50.5 m/m
|
|
|
|
|
|
MEASUREMENT CIRCUIT
|
|
Model Name
|
S 2 3
|
Temperature limists in use
|
-30°C~ 85°C
|
Humidity limits in use
|
95%
|
External structure and size
|
Fig. 1
|
Material
|
Main body
|
Flame resisting
|
Lead
|
Nickel gilding wire
|
Indication
|
Fig. 1
|
|
|
|
|
|
MEASUREMENT CIRCUIT
|
|
|
|